Dark Light

Tinker & Rasor M/1 Low Voltage Holiday Detector


Applications

  • Use on thin film coatings on conductive substrates such as tanks, concrete, etc.

Recommendations:

  • Conforms to standards for low voltage holiday detectors, such as NACE International RP0188

Calibration

  • Recommended Annually

Specifications

  • 67.5v D.C. Output

  • 80 ohm. Resistance for coating on metal

  • 90 ohm. Resistance for coating on concrete

  • (Factory setting is 80 ohm. See Instructions for information on changing setting to 90 ohm)

Dimensions

  • 5′ x 4′ x 2′ Case. 1 lbs. (127mm x 101mm x 50.8mm, 45kg)-Instrument in case

  • 20″ x 5.5″ x 4″, 3 lbs. (508mm x 139.7mm x 101.6mm, 1.35kg)-Shipping

$465.00

M1 Datasheet

New Updates Features

  • 67.5v DC output

  • Power LED

  • Audible & Visual holiday detecting indicators

  • 80kΩ – 90KΩ resistance

  • On-board calibration verification

  • 3.5mm Headphone jack

  • Battery operated (9v) (A/C version available 115v / 240v)

Included in the M/1

  • Instrument with batteries

  • 15’ Ground Cable

  • Wand, 16 with red cable

  • Wand, 18″ extension

  • Sponge electrode 6″ x 3.5″ x 2″ (Ships Compressed, add water)

  • 4 oz. Bottle of “water wetter”

  • Instructions Manual

  • (1) 9v battery (installed)