MFFT 90 Minimum Film Forming Temperature Instrument


  • Measures the minimum film forming temperature of water based coatings
  • Determines the MFFT of latex, emulsions and adhesives
  • -10°C to 90°C operation
  • MFFT Coalescing Agent Case Studies
  • What is MFFT and how is it determined?

$24,155.00

Frequently Bought Together

MFFT Minimum Film Forming Temperature instrument++++
Price for all:   $26,714.00

Ensure your paints and coatings perform correctly.

An accurate MFFT value allows the formulation of products that cure correctly under specified application conditions.

The Rhopoint Minimum Film Forming Temperature Bar (MFFT) is used to determine the minimum film forming temperature and white point in paint and coatings such as water based coatings, polymer dispersions, synthetic latexes and emulsion.

The MFFT also tests adhesives temperature optimization in such areas as coalescence of water-borne adhesives and minimum temperature for epoxy resin cure.

  • Determines the MFFT (minimum film forming temperature) of latex, emulsions and adhesives
  • Easy to use touch screen program control
  • Nickel plated copper platen with an electronically imposed temperature gradient
  • Optional results printer for printing date and time stamped MFFT results
  • -10˚C to 90˚C operation

Standard model (MFFT-90) has ten temperature programs

0123456789
Cold end ˚C-10-505152333435363
Warm end ˚C8131823335060708090

The MFFT Method

A dull, nickel-plated copper platen is cooled at one end electronically and warmed at the other end, while air or nitrogen is caused to flow over the surface as a uniform blanket. The air flow is from cold end to hot end.

To achieve the required uniformity, the air or gas is delivered via a very carefully designed sintered metal distribution block. The design is such that freezing does not take place at the inlet. For use with air, a drying system is incorporated into the housing together with a flow controller. The air dryer contains indicator crystals which are clearly visible in their transparent container. The complete air conditioning system is accessible at the side of the instrument.

Water at normal mains pressure removes the excess heat from the coolers. In environments where the ambient water temperature is high, Rhopoint offer a chiller / recirculating unit to reduce this temperature. Quick release couplings are provided. Water is normally drawn from a laboratory tap and the outlet is run to drain by gravity. Alarms, both audible and visible, protect the cooling water supply.

Temperature sensors are mounted at intervals under the surface of the platen, these are used to control the temperature of the platen in accordance with the chosen program. They are also used to indicate platen temperatures down the length of the bar. A hinged viewing cover over the platen provides thermal insulation while allowing visual inspection of the determination as it progresses.

The use of this instrument may involve hazardous materials and operational procedures. It is the responsibility of the user of this instrument to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 

How does the MFFT work?

1. Select program

Touch-screen intuitive operation with in-built operating guide on-screen

2. Fill application cube with product

3. Move across platen and close perspex lid

4. Coalescence will show in about 90 minutes

 

5. Move cursor

6. Read the exact MFFT point from the display

 

Video

 

Specifications

Instrument Specifications
Conforms toASTM D 2354, ISO 2115
Platen Dimensions483mm × 235mm (L × W)
Air4 l min-1 @ 100 psig
WaterMains pressure; gravity drain
inlet temperature <15°C
Mains110–120V AC or
220–240V AC
Order CodeMFFT, -10˚C to 90˚C 230V – A1212-002
MFFT, -10˚C to 90˚C 115V – A1212-002/115
Dimensions350mm × 550mm × 610mm (H × W × D)
Weight38kg
Packed Weight53.7kg
Packed Dimensions590mm × 800mm × 690mm (H × W × D)
Commodity Code9027 8017
Accessories
Included• Water connectors
• Air connector
• Spare silica gel
• Manual
• 75μm (0.003”) cube applicator
Optional• Chiller – Required when the temperature of the water supply to the instrument is >20ºC higher than the target temperature at the cold end of the selected range.
e.g. Range 0, -10ºC requires a water supply of no higher than 10ºC. If this cannot be supplied then the chiller is required
• Label printer
Extras• Free extended warranty service
• Fast and economic service via our global network of accredited service centres, please visit www.rhopointinstruments.com/distributors/category/service-centre/ for detailed information

What’s in the box

Included:
  • Water connectors
  • Air connector
  • Spare silica gel
  • Manual
  • 75μm (0.003”) cube applicator

 

Downloads

Rhopoint MFFT Instruction Manual

Rhopoint MFFT Datasheet

    SKU: 13302-RHOPOINT Categories: , , Tag:
    Weight85 lbs
    Dimensions22 × 14 × 24 in