Main Menu
Shop
Showing 193–240 of 495 results
- Film Application
BIRD-TYPE FILM APPLICATORS, SINGLE GAP
TQC Bird-type film applicator with one flat edge. One application side for applying 1 pre-defined thickness. The TQC Bird-type applicator single gap is available in film width 50 and 75 mm and suitable for applying a host of different products onto flat and relatively solid substrates. The high-grade stainless steel will not be affected by acid or base elements.
Some models are equipped with removable guidance plates for straight application.
We can not give guarantee of the wet thickness that will be obtained. The wet thickness is dependent upon the solids and vehicle content of the wet material as well as other factors. Film thickness deposited may vary from 40% to 80% of the actual gate clearance of the TQC Bird-type film applicator.
Material:
DAIDO 440C medical grade Martensitic stainless tool steel.
Sub Zero Vacuum hardened (+1756°C to -70°C), hardness HRC 55 (through hardened*) & tempered.Surface treatment:
polishedOverall accuracy:
± 2 µm*Through hardening versus Case-hardening or surface hardening.
Through-hardening means the metal uniformly is hardened throughout the piece. Case- or surface (face / frame) hardening only hardens the top layer of the metal. Once the top layer is degraded excessive wear and tear will occur on the product limiting its life time and affecting accuracy.SKU: n/a - ASTM D 1894, Coefficient of Friction / Peel, ISO 8295, Surface Characteristics, TAPPI T 549
Coefficient of Friction / Peel Tester model 32-76e – – AB5700
ASTM D 1894, Coefficient of Friction / Peel, ISO 8295, Surface Characteristics, TAPPI T 549Coefficient of Friction / Peel Tester model 32-76e – – AB5700
The 32-76e Coefficient of friction / peel tester offers precise and repeatable results with digital force signaling and data acquisition software.
SKU: AB5700 - PH / Conductivity, Salt/Chloride Testing, Sample Preparation, Sample Testing, Surface Cleanliness/Preperations
TQC SHEEN Bresle Kit chloride test – SP7310
PH / Conductivity, Salt/Chloride Testing, Sample Preparation, Sample Testing, Surface Cleanliness/PreperationsTQC SHEEN Bresle Kit chloride test – SP7310
The TQC SHEEN Bresle Kit bresle kit includes all the necessary equipment to execute a bresle test that will indicate the contamination of soluble salts on blast-cleaned surfaces prior to coating. Inside the Bresle Kit – Sodium Chloride Test Kit is a conductivity gauge used for the assessment of soluble salt ions as chlorides, sulphates and nitrates. Read more in the description.
SKU: SP7310 - PH / Conductivity, Salt/Chloride Testing
CHLOR*TEST
CHLOR*TEST was developed for ease of use and to prevent outside and cross contamination. The components are premeasured to ensure accurate results in parts per million and micrograms per square centimeter. In addition, no temperature correction is needed for 41 deg. F to 176 deg. F. Field test inspectors around the world will use this innovative product with confidence on virtually any surface at any angle.
SKU: n/a - Corrosion / Weathering, Hull Roughness Gauge, Surface Characteristics
Hull Roughness Gauge – DC9000
The TQC Hull Roughness Gauge has made the next evolutionary step in hull roughness surveys. Surpassing the industrial standards with an easy to operate 4-way directional push button, graphical representations, storage of data in multiple batches and survey reports in Microsoft Excel®. The whole system fits into a small sized waterproof rugged casing that is allowed as carry on travel luggage and benefits your overseas travel plans.
Controlling the roughness of a ship’s hull plays an important role in the operating costs of a vessel. The roughness of a ship’s hull increases mainly due to corrosion, pitting, plate undulation, mechanical damage, dry spray and above all biofouling. Proper maintenance and the correct application of high-end anti-fouling coatings reduce the hydrodynamic effects and will lead to significant savings on fuel consumption and CO2 emissions.
The hull roughness is measured during in-docking and out-docking. The Hull Roughness Gauge measures the AHR value (Average Hull Roughness) of sea-going vessels. AHR is the ‘mean’ of all the vessel’s hull roughness readings and is the measure against which ship’s performance is correlated.
The TQC Hull roughness Gauge consists of a Control unit and a Sensor unit.
The Hull Roughness Control unit can be operated with just one hand, a 4-way directional push button operates an intuitive menu on a large illuminated display. The neck strap keeps the users’ hands-free when required.The Sensor unit is equipped with three non-slip wheels and a carbide tipped stylus and is moved over the ship’s hull in a horizontal way collecting series of measurements. A set of LED’s indicate the status of the instrument so operation is possible without observing the control unit.
Statistics, time/date and location of each series and the average hull roughness are automatically calculated and stored in the Control unit. Using the supplied USB-cable and software you instantly create inspection reports in Microsoft Excel. Your own company logo and or -details can be incorporated to restyle your reports.
Accuracy: +/- 5 microns or or Memory: Enough for 4 complete surveys done both in- and out-docking, totally over 10.000 readings
Location storage: Simply point and click the hull location in the displayed graphical representation of the ship’s hull.
Units: Microns
Speed: 50 mm/s, with speed indication LED in the Sensor unit
Interface: USB serial to PC connection
Power supply: 4 AA type Alkaline Cells, available worldwide
Calibration certificate: includedSKU: DC9000 - Pit Gages
Bridging Pit Gauge – Standard – N88-09
The Bridging Pit Gauge System allows the Corrosion Inspector to Span over or Cantilever into Large Areas of Weight Loss Corrosion, to obtain accurate and consistent measurements, or cross sections, of Pit Depth. As conditions dictate, the operator can simply use the Main Blade or can assemble the Bridging Pit Gauge up to an over all length of 28″ (725mm).
The contact Surfaces (Blades) of the Bridging Pit Gauge are fitted with an exclusive Knife Edge, so they can be used on Flat, ID (Convex), and OD (Concave) Surfaces, where a flat or notched contact surface can introduces error on Convex Surfaces. Like our Standard Pit Gauges, the Knife Edge gives the operator a clear view of the contact point, and the area being inspected.
With the addition of the optional Magnetic Hold Downs, the operator uses their width to quickly align the Bridging Pit Gauge System to a curved surface. This leaves his hands free to scan through very large areas of weight loss corrosion. This holds true when the Bridge Elements have been assembled with a slight contour on an irregular surface.
Name Part# Description Bridging
Pit GaugeN88-9 Main Blade, Imperial Dial Indicator, Connector Blade, 2-Extender Tees, End Blade, Slider Blade, Hardware, Extra Contact Point, and Carrying Case. SKU: n/a - Appearance Testing, AS 1580 (602.2), ASTM C584, ASTM D2457, ASTM D523, BS 3900-D5, DIN 67530, Gloss / Haze / Hiding Power, Gloss Meters, ISO 2813, ISO 7668, JIS Z 8741, MFT 30-064
Gloss Meters TQC Sologloss, TQC Duogloss, TQC Polygloss
Appearance Testing, AS 1580 (602.2), ASTM C584, ASTM D2457, ASTM D523, BS 3900-D5, DIN 67530, Gloss / Haze / Hiding Power, Gloss Meters, ISO 2813, ISO 7668, JIS Z 8741, MFT 30-064Gloss Meters TQC Sologloss, TQC Duogloss, TQC Polygloss
TQC Portable precision gloss meters for production and laboratory. Suitable for paint and coatings, plastics, automotive parts etc. Made in The Netherlands.
SKU: n/a - Conveyor Ground Tester
Conveyor Ground Test – LD5900
Conveyor ground test with five steps which informs you whether items to be coated are sufficiently grounded. Designed for electrostatic coating applications.
A poor ground of the pieces to be coated may result in a poor quality of the electrostatic coating work. Coating thickness may not be sufficient or the pieces may not be even covered.
Consult your paint manufacturer or the supplier of your spray equipment for correct values.
The LD5900 is a low cost, easy to use ground check that is battery operated.
SKU: LD5900 - ASTM D823, Film Application, Film Application Accessories
Cube Applicators
TQCSHEEN Cube applicator for applying a paint film of uniform thickness. Ideal for applying paint on test panels used on for instance a drying time recorder.
AB3700 – TQC Cube Applicator, gaps 38 & 76µm
AB3701 – TQC Cube Applicator, gaps 50 & 100µm
AB3702 – TQC Cube Applicator, gaps 75 & 150µm
AB3703 – TQC Cube Applicator, gaps on request (µm)
AB3705 – TQC Cube Applicator, gaps 1,5 & 3 mil
AB3706 – TQC Cube Applicator, gaps 2 & 4 mil
AB3707 – TQC Cube Applicator, gaps 3 & 6 mil
AB3708 – TQC Cube Applicator, gaps on request (mil)
AB3709 – TQC Cube Applicator, gaps 6 & 8 mil
AB3710 – Cube Applicator 50mm wide, gaps 50 & 100µm, reservoir Ø: 43 mm / 1.69 inch
AB3711 – Cube Applicator 50mm wide, gaps 150 & 200µm, reservoir Ø: 43 mm / 1.69 inch
AB3712 – TQC Cube Applicator, gaps 6 & 8 mil
SH0077 – 50mm Cube Film Applicator 150-200µmSKU: n/a - Climate Testing, Temperature, Temperature and Climatic Testing
Sato SK-L200THII Alpha datalogger+SK-LTHII-1 probe – HM8020
Climate Testing, Temperature, Temperature and Climatic TestingSato SK-L200THII Alpha datalogger+SK-LTHII-1 probe – HM8020
Sato SK-L200THII Alpha datalogger+SK-LTHII-1 probe – HM8020
Extremely compact data logger for recording temperature and air humidity. Complete with attached combiprobe (T/RV). A wire-combiprobe is optional. Directly programmable from the keypad or PC. Complete with attached combiprobe, USB cable and evaluation software.
SKU: HM8020 - ASTM D3276-07, Climate Testing, Dewpoint, ISO 8502-4, Recorders / Dataloggers, Temperature, Temperature and Climatic Testing
DewCheck 4 Series 2 – Dewpoint Meter | Dewmeter DC7100
ASTM D3276-07, Climate Testing, Dewpoint, ISO 8502-4, Recorders / Dataloggers, Temperature, Temperature and Climatic TestingDewCheck 4 Series 2 – Dewpoint Meter | Dewmeter DC7100
The TQC DewCheck 4 – Dewpoint Meter (DPM)/ Dewmeter is an extremely versatile dewpoint meter to measure and record all climate parameters required to treat surfaces. This easy to use and robust dewmeter conforms to ISO 8502-4 & ASTM D3276-07 and measures the relative humidity (%RH), ambient temperature (Ta) and surface temperature (Ts) and calculates the dewpoint temperature (Td) and the difference between the dewpoint temperature and the surface temperature (ÄT). The difference between the surface temperature and dewpoint temperature indicates the optimal climate conditions for painting. All parameters can be stored in the dew meter’s memory, tagged with a date and time.
For communication between DewCheck 4 dewmeter and a PC the DewCheck dew meter USB cable is standard supplied. To analyze the data the DewCheck 4 comes with the special Ideal Finish Analysis software. This software is the most advanced temperature and humidity monitoring software package for Dew-point Meters available today. It offers user friendly reporting functions for standard production work as well as advanced calculations for in depth analysis of the climate parameters prior to coating. Detailed graphic representations and custom reports help to make the right decisions.
SKU: DC7100 - Temperature, Temperature and Climatic Testing
Infrared Thermometer -30 +270°C – TE1004
Pocket sized infrared thermometer with laser pointer to measure surface temperature without making contact. The laser pointer identifies the target area easily. An illuminated display allows working in dark or poorly lit environments.
Fast and simple operation, just point and shoot and the surface temperature is shown immediately. Typical applications are with surfaces that are hard to reach, moving objects or electrical parts.
SKU: TE1004 - Temperature, Temperature and Climatic Testing
Infrared thermometer (-50 to + 750° C) – TE1005
A user-friendly TQC Infrared Thermometer Standard designed to measure surface temperature without making contact under harsh industrial circumstances. The laser pointer identifies the target area while rubber parts on the housing protect the instrument against mechanical damage. An illuminated display allows working in dark or poorly lit environments.
SKU: TE1005 - Temperature, Temperature and Climatic Testing
Eco Thermapen thermometer -49.9 to +149.9°C – TE0027
TQC Precision Thermometer Temperature Range: -49.9 to +149.9°CResolution: 0.1°C (°F alterable)Accuracy: ±0.5°C between -49.9 to 99.9°C, ±1°C above 100°CBattery: MN2400 (AAA)
Battery Lifetime: 8000 hours
Display: 15mm LCD
Dimensions: 19 x 52 x 155mm
Weight: 76 gramThe TQC Precision Thermometer is a handy pocket size thermometer with foldable stainless steel probe. Suitable for measurements in liquids and semisolids. Large clear display, ergonomic design and easy to clean. The instrument is equipped with an ON/OFF, MAX/MIN switch and can easily be set to Fahrenheit if necessary.
SKU: TE0027 - Climate Testing, Dewpoint, Temperature and Climatic Testing
Bacharach STYLE Sling Psychrometer – Certified
Climate Testing, Dewpoint, Temperature and Climatic TestingBacharach STYLE Sling Psychrometer – Certified
A Bacharach Sling Psychrometer is for indicating percent relative humidity on the basis of the wet bulb-dry bulb thermometer principle. The plastic case of the instrument is equipped with conversion scale for calculating the percent relative humidity.
Includes NIST Traceable Certification.
SKU: 0012-7012 - Accessory Products, CurveX Tools and Supplies, Temperature, Temperature and Climatic Testing
CurveX 4 Oven Logger Kit – CX4010
Accessory Products, CurveX Tools and Supplies, Temperature, Temperature and Climatic TestingCurveX 4 Oven Logger Kit – CX4010
Profiling an industrial powder coating oven starts here with the CurveX 4 8-channel Oven Logger Kit. It contains all necessary items, just add the desired magnetic or clamp-type probes to make the oven logger kit complete.
Includes:
• CurveX 4 Oven Logger with Ideal Finish Analysis Software
• Insulation Box
• Energy Absorber
• Silicone Seal
• Probe Identification Set
• CaseSKU: CX4010 - CurveX Tools and Supplies, Temperature, Temperature and Climatic Testing
CurveX 4 Oven Temperature Data Logger – CX4005
CurveX Tools and Supplies, Temperature, Temperature and Climatic TestingCurveX 4 Oven Temperature Data Logger – CX4005
The CurveX 4 is an intelligent temperature data logging system that was specially designed to control curing processes in the coating industry. The CX4005 has 8 k-type channels.
Included:
• CurveX 4 Oven Logger
• Factory calibrated, calibration certificate
• Ideal Finish Analysis Software
• USB-C Cable
• USB Memory stick
• Plastic Carrying CaseSKU: CX4005 - Elasticity Testing, Resistance & Deformation
Cylindrical Bend Test 100mm Incl Mandrel Set (Imperial) – SP1822
Elasticity Testing, Resistance & DeformationCylindrical Bend Test 100mm Incl Mandrel Set (Imperial) – SP1822
The TQC Cylindrical Bend Test is a very robust yet elegant testing instrument to indicate the elasticity, elongation and adhesion of a paint film at bending stress. The TQC Cylindrical Bend Test is designed to perform tests according to the latest standard ASTM D522, assessing the resistance of a coating, paint, varnish or related products to cracking and/or detachment from a surface when, subjected to bending around a cylindrical mandrel under standard conditions.
The diameter of the mandrels are (in inches): 1/8, 1/4, 3/8, 1/2, 5/8, 3/4, 1
The luxurious desktop holder with 7 mandrels can also be wall mounted.SKU: SP1822 - ASTM D522, Elasticity Testing, Resistance & Deformation
Cylindrical Bend Test 100mm Incl Mandrel Set (Metric) – SP1820
ASTM D522, Elasticity Testing, Resistance & DeformationCylindrical Bend Test 100mm Incl Mandrel Set (Metric) – SP1820
The TQC Cylindrical Bend Test is used to determine the elasticity adhesion and elongation of paint on sheet metal in accordance with ISO 1519. A test panel (max. size 150 x 100 mm) is bent over a cylindrical mandrel. The smaller the diameter of the mandrel, the larger the tension on the coating. The test panel is then checked for cracks or damage in the coating.
The luxurious desktop holder with 14 mandrels can also be wall mounted.
Mandatory test in Qualicoat, QIB and GSB accredited laboratories.
SKU: SP1820 - ASTM D1084, ASTM D5725, Contact Angle Testing, Tappi T588
DAT 1121 Dynamic Contact Angle Tester – PG1050 or DAT 1122 – PG1051
ASTM D1084, ASTM D5725, Contact Angle Testing, Tappi T588DAT 1121 Dynamic Contact Angle Tester – PG1050 or DAT 1122 – PG1051
DAT 1121 Dynamic Contact Angle Tester – PG1050 – or – DAT 1122 Dynamic Contact Angle Tester – PG1051
The DAT measures the contact angle (dynamic and static), surface tension, penetration, surface energy and spreading. The instrument uses a sophisticated camera to capture the fall/ shape of the drop, the shape on the sample and eventually the penetration. The pump and the camera work closely together. This is critical to have the correct amount of liquid and have each test start at the same time.
SKU: n/a






































